Premium Programmable Thermostat
Safety & Installation
Instructions
Model 8570
READ AND SAVE THESE INSTRUCTIONS
Vista de página 0
1 2 3 4 5 6 ... 39 40

Resumo do Conteúdo

Página 1 - Instructions

Premium Programmable ThermostatSafety & InstallationInstructionsModel 8570READ AND SAVE THESE INSTRUCTIONS

Página 2 - TABLE OF CONTENTS

- 6 -(4) SET THE CONFIGURATION DIP SWITCHES ON THE THERMOSTAT CIRCUIT BOARDONH/CGASMULTI6504HPELECAHCSINGLEFigure 5There are four dip switcheslocated

Página 3

If installing this thermostat as part of a Model 6504 Intelligent Zone System, refer to the Model 6504Installation Manual for wiring and checkout proc

Página 4 - SAFETY INSTRUCTIONS

- 8 -1. Run a cable with the correct number of wires (see table) from the thermostat to the HVAC equipment.2. Strip 1/4" of insulation from the e

Página 5 - MODEL 8570 SPECIFICATIONS

- 9 -Diagram 1: Single-Stage Furnace and AC

Página 6 - WIRE REQUIREMENTS

- 10 -Diagram 2: Two-Stage Furnace and AC

Página 7

- 11 -Diagram 3: Two-Stage Roof Top Unit

Página 8 - (2) OPEN THE THERMOSTAT

- 12 -Diagram 4: Boiler with AC

Página 9

- 13 -Diagram 5: Radiant Floor 1st Stage Heat with Furnace 2nd Stage Heat and AC

Página 10

- 14 -Diagram 6: Single-Stage Heat Pump

Página 11

- 15 -Diagram 7: Two-Stage Heat Pump

Página 12

TABLE OF CONTENTSPAGESPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1WIRE REQUIREMENTS. . . . . . . . . . . . . . . . . . .

Página 13

- 16 -(6) OPTIONAL – INSTALL AN APRILAIRE MODEL 8052 OUTDOOR TEMPERATURE SENSORNote: If an AHC is to be installed, do not wirean outdoor temperature s

Página 14

- 17 -2. Run a 2-wire cable from the sensor to the thermostat.3. Take a resistance measurement before connecting to the ODT and CIR GND terminals to v

Página 15

CIRGNDIDSODTZAZBCFigure 7- 18 -

Página 16 - Diagram 4: Boiler with AC

Note: The AHC uses its own outdoor temperature sensor,which is read by the thermostat. If an AHC is to be installed,do not wire an outdoor temperature

Página 17

B2203201 Rev. B24VBYPASSI+ RI-POWERHC ODTTEST/ RESET 2354617AUTOMATIC MODEOFF NORMAL OFF CABFigure 8AHC must be powered by acontinuous supply – do not

Página 18

1. Mount the indoor temperature sensor.• Locate the sensor as you would locate a thermostat.• Maximum wire length from sensor to thermostat is 300 fee

Página 19

- 22 -CIRGNDIDSODTZAZBCFigure 9

Página 20

- 23 -(9) THERMOSTAT STARTUP – STAND ALONE APPLICATIONSEQUIPMENTSTATUSOUTDOORTEMPERATUREROOMTEMPERATUREMESSAGECENTERSETPOINTSUP/DOWN BUTTONSMULTI-FUNC

Página 21

NOTE: Refer to the Owner’s Manual for thermostat operating instructions.1. PLACE THE THERMOSTAT ON THE BASE.2. TURN ON POWER TO THE HVAC SYSTEM.• The

Página 22 - Figure 7

Symptom CauseMiswiring – Check wire colors to verify I- at AHC is connected to I- at thermostat and I+ is connected to I+.No RH display, no outdoor A

Página 23

PAGE7. OPTIONAL – INSTALL AN AUTOMATICHUMIDIFIER CONTROL (AHC) . . . . . . . . . . . . . 198. OPTIONAL – INSTALL AN INDOOR TEMPERATURE SENSOR . . . .

Página 24 - AHC must be powered by a

- 26 -6. CHECK HEATING OPERATIONNotes:1. To avoid the minimum off times during systemcheckout, always start and end the check outprocedure in the OFF

Página 25

Symptom CauseThermostat does not call for heatMinimum-off times. Change the mode to OFF first, then change the mode to HEAT and make a call for heat.H

Página 26 - Figure 9

- 28 -7. CHECK COOLING OPERATIONNotes:1. To avoid the minimum off times during systemcheckout, always start the check out procedure in the OFF mode.2.

Página 27

- 29 -8. CHECK EMERGENCY HEAT OPERATION(Heat Pumps Only)Notes:1. To avoid the minimum off times during system checkout,always start the check out proc

Página 28

- 30 -1. DIFFERENTIALDetermines the temperature above/below the temperaturesetting at which the heating or cooling equipment will turnon. For example,

Página 29 - Symptom Cause

2. OFFSETAll thermostats are factory calibrated to be accurate to within±1° of true temperature. An offset is available to allow foragreement with fie

Página 30

- 32 -4. BALANCE POINTS (HEAT PUMPS ONLY)This feature is only available when the thermostat has beenconfigured to operate heat pumps (see SET THECONFI

Página 31

5. INPUT DEALER CONTACT INFORMATIONDuring thermostat operation, the two multi-function buttonsare labeled INFO and MENU. When the INFO button ispresse

Página 32

- 34 -6. BLOWER EXTENSION FOR HUMIDITY CONTROLIf the heating equipment has not run long enough to allow thehumidifier to meet the humidity demand, the

Página 33

7. MONITORS – AIR FILTER, SERVICE HUMIDIFIER, UV LAMP, SERVICE HVACThe thermostat monitors time and can display scheduledreminders for the user to ser

Página 34

WARNING1. 120 Volts may cause serious injury from electrical shock. Disconnect electrical power to the HVAC equipment beforestarting installation. Thi

Página 35 -  or  button to

DP 10006198 01.05B2203358B Printed in U.S.A.P.O. BOX 1467 • MADISON, WI 53701-1467

Página 36

- 1 -MODEL 8570 SPECIFICATIONSElectricalThermostat Voltage: 24-volts ± 20% AC or DCTotal Load Current: 2ASingle Output Load Current: 1ASolid State Out

Página 37

- 2 -Figure 1 and the table show the number of wires that must be available at the thermostat in stand-alone thermostat systems (i.e. not aspart of an

Página 38

- 3 -(1) SELECT A MOUNTING LOCATIONIf installing the thermostat alone…• Mount on an interior wall, in a frequently occupied space.• Keep the thermosta

Página 39

(2) OPEN THE THERMOSTATUse your hands to pull the thermostat face off of the base. Separate one side at a time. There are latches oneither side of the

Página 40 - B2203358B Printed in U.S.A

- 5 -(3) MOUNT THE THERMOSTAT BASE TO THE WALL1. Place the wire opening in the base over the wire entryhole in the wall. Level the base (for appearanc